        Product current:home > Product > XRW-300C-3 Thermal deformation, Vica softening point temperature tester C
        XRW-300C-3 Thermal deformation, Vica softening point temperature tester C

        XRW-300C-3 Thermal deformation, Vica softening point temperature tester C

         

        Overview

        Mainly used for plastic, hard rubber, nylon, electrical insulation materials, long fiber reinforced composite materials, high strength thermosetting laminated materials and other non-metallic materials such as thermal deformation temperature and Vica softening point temperature determination. Easy to operate, accurate control, is a highly intelligent test instrument, widely used in colleges and universities, scientific research institutions and product quality supervision and inspection units.

        The machine with Windows 98, Windows2000 or Windows7 Chinese operation interface, real-time monitoring test temperature, real-time drawing temperature and deformation curve, print test report, to achieve historical storage, mouse click deformation and temperature curve at any place, the interface will automatically display the deformation and temperature value. With the testing machine automatic lifting system, the selection of high-precision displacement sensor to measure deformation.

         the working principle

         VST meter: Put the sample in the liquid medium or heating box, and measure the temperature of 1mm when the standard press needle is pressed into the sample cut from the pipe or pipe fitting under the action of (50+1) N force under the condition of constant temperature rise.

        Thermal deformation (HDT) definition: the standard sample is placed flat (preferably) or side-standing way to bear a three-point bending constant load, so that it produces one of the bending stresses specified in the relevant part of GB/T 1634, under the condition of constant temperature rise, the temperature when the standard deflection corresponding to the specified bending strain increment is measured.

        Side standing: divided into "flat" and "side standing" two, and clearly pointed out that the preferred flat way, the side standing way is only an alternative, and will be revoked.

        Span: the distance between the two contact lines between the support and the sample is changed from one (100mm) to two 64mm(flat) and 100mm (side standing), and the tolerance requirements are specified that the span L should be (100+1) mm, and the span L is (64+1) mm.

        Note: Can be arbitrarily span according to user requirements.

        Three methods of load deformation temperature

        Method A: 1.80Mpa bending stress

        Method B: 0.45MPa bending stress

        Method C: 8.00MPa bending stress

        Calculation of applied force:

        In the three-point loading method used in GB/T 1634, the force F applied to the sample, in N, as a function of the bending stressf δ, is calculated by formula 1 or 2:

        If the sample is placed preferentially (flat)

        Formula 1 2δf  b •h

        F=

        3L

        If the specimen is placed in an alternative (side-standing) manner:

         

        Formula 2 2δf  h •b

        F=

        3L

        In formula:

        F - load in Newtons (N)

        δf -- bending stress on the surface of the specimen in MPa

        b -- specimen width, in millimeters (mm)

        h -- specimen thickness, in millimeters (mm)

        L -- The distance (span) between the specimen and the contact line of the support, in mm (mm)

        Schedule 1 - Standard deflections corresponding to different sample heights

        Lay the 80 mm x 10 mm x 4 mm sample for the test flat

        Sample height (sample thickness h) /mm

        Standard deflection /mm

        3.8

        3.9

        4.0

        4.1

        4.2

        0.36

        0.35

        0.34

        0.33

        0.32

        Note 1: The table gives the standard deflection used in flat tests for specimens of preferred size

        Note 2: The thickness shown in Table 1 reflects the allowable range of variation in sample size.

         

        Table 2 corresponds to standard deflections for different sample heights

        120mm x (3.0-4.2)mm x (9.8-15.0)mm for the side stand test

        Sample height (sample thickness h) /mm

        Standard deflection /mm

        9.8-9.9

        10.0-10.3

        10.4-10.6

        10.7-10.9

        11.0-11.4

        11.5-11.9

        12.0-12.3

        12.4-12.7

        12.8-13.2

        13.3-13.7

        13.8-14.1

        14.2-14.6

        14.7-15.0

        0.33

        0.32

        0.31

        0.30

        0.29

        0.28

        0.27

        0.26

        0.25

        0.24

        0.23

        0.22

        0.21

         

         

         

         

         

         

        Meet the standard

        Standard No.

        Standard name

         

        GB/T 1633

        Thermoplastics Vica softening temperature (VST) determination

         

        GB/T 1634

        Plastics - Determination of load deformation temperature

         

        GB/T 8802

        Thermoplastic pipes and fittings -- determination of Vica softening temperature

         

        ISO 2507-1

        Thermoplastics Pipes and Fittings - Vicat Softening Temperature

         

        ISO 2507-2

        ISO 75

        Plastics —Determination of temperature of deflection under load

        ISO 306

        Plastics -- Thermoplastic materials -- Determination of Vicat softening temperature

        ASTM D 1525-00

        Standard Test Method for Vicat Softening Temperature of Plastics

        ASTM D 648

        Standard Test Method for Deflection Temperature of Plastics Under Flexural Load in the Edgewise Position

         Technical parameters

        XRW-300C-3 thermal deformation, Vica softening point temperature tester

        Temperature control range

        Room temperature ~ 300℃

        Heating rate

        120℃/h (thermal deformation test), 50℃/h (Vica test)

        Maximum temperature error

        Plus or minus 0.5 ℃

        Temperature measuring point

        1

        Number of specimen racks

        3

        Deformation measuring tools

        Displacement sensor

        Deformation measuring range

        0 to 10mm

        Deformation measurement error

        + / - 0.005 mm

        Sample support span

        64mm(flat preferred), 100mm (side stand)

        Heating medium

        Methyl silicone oil or transformer oil

        Cooling method

        Natural cooling above 150℃, water cooling or natural cooling below 150℃

        Temperature protection

        Dual temperature control upper limit protection

        Control mode

        MCU and PC distributed control system

        Sample extraction method

        Sample stand automatic lifting system

        Instrument Dimensions

        640X400X1300mm

        Power source

        2500VA  220VAC  50HZ

         

         Configuration

         

        Name

        Quantity

        Host

        One

        Sample holder

        Three

        Hot deformation indenter

        Three

        Vica press needle

        Three

        Electric box

        One (attached to the main engine)

        Displacement sensor

        Three branches

        Temperature sensor

        One

        Power cord

        One

        Weights

        A set

        Signal wire

        One (attached to the main engine)

        Brand name computer

        One

        A color inkjet printer

        One

        A Chinese version of the operating system under the test software

        1 set (lifetime maintenance)

         

         

        the previous:WDE series ring stiffness testing machine next:POT-M tube light permeability tester